Table 1. 37.5 mm (1.5 inch) Nominal Size
Sieve Size Control Points Restricted Zone
(mm) (U.S.) Lower Upper Lower Upper
50 2 inch 100 - - -
37.5 1.5 inch 90 100 - -
25 1 inch - 90 - -
19 3/4 inch - - - -
12.5 1/2 inch - - - -
9.5 3/8 inch - - - -
4.75 No. 4 - - 34.7 34.7
2.36 No. 8 15 41 23.3 27.3
1.18 No. 16 - - 15.5 21.5
0.60 No. 30 - - 11.7 15.7
0.30 No. 50 - - 10.0 10.0
0.15 No. 100 - - - -
0.075 No. 200 0 6 - -

 

Table 2. 25 mm (1 inch) Nominal Size
Sieve Size Control Points Restricted Zone
(mm) (U.S.) Lower Upper Lower Upper
37.5 1.5 inch 100 - - -
25 1 inch 90 100 - -
19 3/4 inch - 90 - -
12.5 1/2 inch - - - -
9.5 3/8 inch - - - -
4.75 No. 4 - - 39.5 39.5
2.36 No. 8 19 45 26.8 30.8
1.18 No. 16 - - 18.1 24.1
0.60 No. 30 - - 13.6 17.6
0.30 No. 50 - - 11.4 11.4
0.15 No. 100 - - - -
0.075 No. 200 1 7 - -

 

Table 3. 19 mm (3/4 inch) Nominal Size
Sieve Size Control Points Restricted Zone
(mm) (U.S.) Lower Upper Lower Upper
25 1 inch 100 - - -
19 3/4 inch 90 100 - -
12.5 1/2 inch - 90 - -
9.5 3/8 inch - - - -
4.75 No. 4 - - - -
2.36 No. 8 23 49 34.6 34.6
1.18 No. 16 - - 22.3 28.3
0.60 No. 30 - - 16.7 20.7
0.30 No. 50 - - 13.7 13.7
0.15 No. 100 - - - -
0.075 No. 200 2 8 - -

 

Table 4. 12.5 mm (1/2 inch) Nominal Size
Sieve Size Control Points Restricted Zone
(mm) (U.S.) Lower Upper Lower Upper
19 3/4 inch 100 - - -
12.5 1/2 inch 90 100 - -
9.5 3/8 inch - 90 - -
4.75 No. 4 - - - -
2.36 No. 8 28 58 39.1 39.1
1.18 No. 16 - - 25.6 31.6
0.60 No. 30 - - 19.1 23.1
0.30 No. 50 - - 15.5 15.5
0.15 No. 100 - - - -
0.075 No. 200 2 10 - -

 

Table 5. 9.5 mm (3/8 inch) Nominal Size
Sieve Size Control Points Restricted Zone
(mm) (U.S.) Lower Upper Lower Upper
12.5 1/2 inch 100 - -
9.5 3/8 inch 90 100 - -
4.75 No. 4 - 90 - -
2.36 No. 8 32 67 47.2 47.2
1.18 No. 16 - - 31.6 37.6
0.60 No. 30 - - 23.5 27.5
0.30 No. 50 - - 18.7 18.7
0.15 No. 100 - - - -
0.075 No. 200 2 10 - -

 

 

 

 

 